Technical information / General properties
The details your project needs.
Two thicknesses. The same nominal tile size. The figures below are taken from the manufacturer’s general properties for CNT Conductive Tile.
- Thickness options
- 2.0 / 3.0 mmTolerance: ±0.15 mm
- Nominal size
- 600 mmPublished tolerance: ±0.5 mm
- Weight per area
- 3.9 / 5.85 kg/m²2.0 mm / 3.0 mm options
| Property | Test method | Unit | 2.0 mm | 3.0 mm |
|---|---|---|---|---|
| Total thickness | KS-3802 | mm | 2.0 ± 0.15 | 3.0 ± 0.15 |
| Nominal size | KS-3802 | mm | 600 ± 0.5 | 600 ± 0.5 |
| Weight per area | — | kg/m² | 3.9 | 5.85 |
| Perpendicularity | — | mm | ≤ 0.25 | ≤ 0.25 |
| Dimensional stability / MD | KS-3802 | % | ≤ 0.25 | ≤ 0.25 |
| Dimensional stability / CD | KS-3802 | % | ≤ 0.25 | ≤ 0.25 |
| Residual indentation / 45°C | KS-3802 | mm | ≤ 1.2 | ≤ 1.2 |
| Stain resistance | — | — | No swelling, colour or gloss change | No swelling, colour or gloss change |
| Char length | KS-3802 | mm | ≤ 100 | ≤ 100 |
This table summarises the manufacturer’s general product data. Request current technical documents for project-specific test reports, electrical resistance and installation requirements. Manufacturer product information ↗
Request technical informationFREQUENTLY ASKED
Clear answers to your questions.
How do the 2.0 and 3.0 mm options differ?
The published differences are nominal thickness and weight per area: 3.9 kg/m² for 2.0 mm and 5.85 kg/m² for 3.0 mm. Both options have a published nominal size of 600 mm.
Is material conductivity the electrical resistance of a floor?
No. The S/cm figures in the technology comparison refer to carbon materials. Resistance and suitability of a completed flooring system should be assessed against technical documents for that system and its installation conditions.
Which ESD standards are referenced?
The manufacturer’s product description refers to ANSI/ESD S20.20 and IEC 61340-5-1. You can request current product and system test reports relevant to your project with your technical team.